Walk-in Pharmaceutical Stability Chamber - Operating Principle · Key Advantages · Service Commitment

2026-11-27 33

1. Product Overview

The Labonce walk-in pharmaceutical stability chamber (8–80 m³, dimensions customizable to site layout) is designed in accordance with ICH Q1 and GB/T 10586-2006. It is used for long-term stability studies of APIs, finished dosage forms and packaging materials, maintaining standard conditions such as 25°C/60%RH and 30°C/65%RH, and supports on-site GMP/cGMP qualification.


Figure 1  Complete unit: independent control cabinet, hollow tempered glass window and insulated door

 

2. Operating Principle

The chamber works as a closed loop of sensor measurement, controller calculation and actuator action, with temperature and humidity regulated independently and compensating each other.

 

1.Closed-loop temperature and humidity control: Pt100 temperature sensors and imported capacitive humidity sensors collect chamber data in real time. The controller compares readings with set points, performs PID calculation and drives the compressor, heater, humidifier and dehumidification system, keeping cooling, heating, humidification and dehumidification in dynamic balance.

 

2. Cooling and heating: the primary cooling source is an original imported hermetic inverter compressor, supported by a backup unit. Heating uses stainless-steel electric heaters with circulation fans for fast, stable response without overshoot.

 

3. Humidification and dehumidification: humidification supplies vaporized clean water into the air duct, while dehumidification removes moisture by condensation on the evaporator. Humidity is controlled within 20–80%RH with fluctuation ≤±2.0%RH.

 

4. Airflow organization: the newly designed air duct supplies air from the top, distributes it through an equalizing plate and returns it from both sides, creating a stable circulation that eliminates dead zones and local overshoot — the key to temperature and humidity uniformity in large chambers.


Figure 2  Air duct and airflow design: top supply, side return, uniform circulation throughout the chamber

 

3. Key Advantages

  • Proven performance: 20–45°C with fluctuation ≤±0.5°C and deviation ≤±1.0°C; 20–80%RH with fluctuation ≤±2.0%RH and deviation ≤±3.0%RH, meeting ICH Q1 stability conditions.
  • Energy saving: inverter compressor and optimized air duct deliver significantly lower power consumption than fixed-speed systems during continuous operation, cutting laboratory running costs.
  • Backup refrigeration: main and standby units switch automatically, so a single failure does not stop the chamber — essential for stability studies that run for years.
  • Compliant data: 7-inch or larger color touchscreen, three-level user authority, audit trail, tamper-proof USB export, built-in micro printer, and more than five years of temperature and humidity data storage.
  • Multiple safety protections: compressor overheat and overpressure protection, water-shortage and dry-burn protection, independent over-temperature audible and visual alarm, with optional power-failure SMS alarm.
  • Flexible capacity: standard models of 8/15/20/33/40/60/80 m³, plus custom sizes to fit site layout; multiple chambers can be combined into a stability testing room.


Figure 3  SUS304 stainless steel interior, anti-slip floor and adjustable stainless steel shelving

 

4. Service Commitment

  • 12-month warranty: 12 months from acceptance, with free repair or replacement for non-human damage.
  • FAT/SAT support: factory acceptance test (FAT) and site acceptance test (SAT) protocols, record sheets and IQ/OQ documentation to support customer GMP qualification.
  • 24-hour response: reply with a solution within 24 hours on working days; fast-moving spare parts in stock, with local service partners supporting overseas customers.

 

From selection and qualification to long-term operation, Labonce delivers a stability testing environment that is verifiable and built to last.

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.